Power that Targets. Results that Show.
A picosecond Nd:YAG platform for tattoo, pigmentation and skin-rejuvenation workflows.
Device overview
A picosecond Nd:YAG platform for tattoo, pigmentation and skin-rejuvenation workflows.
An articulated laser delivery arm with aerospace aluminum construction supports flexible handpiece positioning for the picosecond configuration.
Explore the articulated armApplication categories support product discussion. They do not establish clearance or suitability for every configuration.
BENEATH THE SURFACE
Explore pigment-targeted pulses and the different interaction created by a fractional optic.

Short laser pulses are absorbed by selected pigment particles. Rapid energy deposition produces thermal and mechanical effects that can fragment tattoo ink; the body's immune processes gradually handle the fragments. Wavelength and pulse duration help determine which pigment is targeted.

A fractional optic concentrates picosecond energy into separated microscopic interaction zones. With suitable settings, these focal effects can initiate a remodeling response while leaving tissue between the zones untreated. This differs from vaporizing continuous channels through the skin.
Illustrative tissue interactions, not to scale. Treatment response depends on the selected handpiece, settings and individual assessment.
| Device | Pulse technology | Maximum pulse energy at 1064 / 532 nm |
|---|---|---|
| PicoVive | Picosecond | 500 / 250 mJ |
| PicoFusion | Picosecond + Q-switched modes | Pico: 500 / 250 mJ; Q-switched: 1200 / 500 mJ |
| NanoVive | Q-switched; SPT and long-pulse modes | Q-switched: 1200 / 500 mJ |
PicoFusion and NanoVive also list SPT 1064 nm up to 1400 mJ and hair-removal mode up to 60 J/cm². Pulse energy (mJ) and fluence (J/cm²) are different measures. Maximum values depend on mode; energy alone does not determine suitability or results.
| Consideration | Dedicated device | Apolo One / PrimaVive |
|---|---|---|
| Service focus | A focused technology for a defined workflow | Several technology options on one platform |
| Configuration | Compare the model’s pulse modes and available optics | Specify each required module, handpiece and accessory |
| Clinic planning | Consider room allocation and simultaneous appointments | Consider shared-platform scheduling, training and future options |
Laser-Induced Optical Breakdown (LIOB) is a physical phenomenon where focused laser energy, typically from ultrashort pulse lasers, creates a microplasma by ionizing tissue at the focal point. This rapid ionization creates localized cavitation and micro-disruption within the targeted tissue while helping limit thermal exposure to surrounding areas. The resulting micro-injury is intended to support collagen remodeling and skin renewal while limiting impact on the epidermis.
The fractional lens array creates pixel-sized perforations in a 5×5 or 6×6 non-ablative pattern, evenly distributing energy across the treated area. It can also perform non-sequential scanning, which increases the interval between adjacent pulses and improves heat dissipation. This process stimulates collagen production, triggers neocollagenesis, and rejuvenates the target tissue.
Our advanced IGBT based medical power supply delivers exceptional efficiency and performance. Compared to conventional systems, it achieves significantly higher power conversion efficiency with reduced energy loss and minimal heat generation, ensuring stable and reliable operation during extended clinical use.
Operating at frequencies reaching several hundred kilohertz, the system provides ultra fast response times measured in tens of nanoseconds. This allows precise energy delivery and superior pulse control for consistent treatment outcomes.
The highly integrated IGBT module design results in a more compact footprint with reduced weight, improving overall system reliability while supporting high power demands.
The system utilizes an integrated liquid-cooled thermal management architecture engineered to maintain stable performance during continuous high-power operation. Heat is efficiently transferred from critical internal components through a closed-loop liquid cooling circuit to a high-efficiency radiator featuring precision-machined copper fin structures.
The liquid medium enables rapid and uniform heat extraction, while copper’s high thermal conductivity maximizes thermal exchange at the radiator level. This design ensures consistent temperature control across demanding treatment cycles and extended use.
By actively regulating thermal load at the source, the system minimizes heat accumulation, reduces stress on electronic and optical components, and enhances overall system stability. The result is improved performance consistency, quieter operation, and extended service life in clinical environments.
BENEATH THE SURFACE
Explore pigment-targeted pulses and the different interaction created by a fractional optic.

Short laser pulses are absorbed by selected pigment particles. Rapid energy deposition produces thermal and mechanical effects that can fragment tattoo ink; the body's immune processes gradually handle the fragments. Wavelength and pulse duration help determine which pigment is targeted.

A fractional optic concentrates picosecond energy into separated microscopic interaction zones. With suitable settings, these focal effects can initiate a remodeling response while leaving tissue between the zones untreated. This differs from vaporizing continuous channels through the skin.
Illustrative tissue interactions, not to scale. Treatment response depends on the selected handpiece, settings and individual assessment.
| Device | Pulse technology | Maximum pulse energy at 1064 / 532 nm |
|---|---|---|
| PicoVive | Picosecond | 500 / 250 mJ |
| PicoFusion | Picosecond + Q-switched modes | Pico: 500 / 250 mJ; Q-switched: 1200 / 500 mJ |
| NanoVive | Q-switched; SPT and long-pulse modes | Q-switched: 1200 / 500 mJ |
PicoFusion and NanoVive also list SPT 1064 nm up to 1400 mJ and hair-removal mode up to 60 J/cm². Pulse energy (mJ) and fluence (J/cm²) are different measures. Maximum values depend on mode; energy alone does not determine suitability or results.
| Consideration | Dedicated device | Apolo One / PrimaVive |
|---|---|---|
| Service focus | A focused technology for a defined workflow | Several technology options on one platform |
| Configuration | Compare the model’s pulse modes and available optics | Specify each required module, handpiece and accessory |
| Clinic planning | Consider room allocation and simultaneous appointments | Consider shared-platform scheduling, training and future options |
PicoVive is our third-generation picosecond laser, featuring a 300 ps driver fine-tuned to 330 ps to maximize lens durability while maintaining the same efficacy associated with the 300 ps range. Picosecond lasers are considered superior because they deliver energy in extremely short bursts—measured in trillionths of a second—allowing them to create powerful photoacoustic effects instead of relying primarily on heat. This rapid pressure-wave mechanism shatters pigment into much finer particles than nanosecond lasers, making removal of tattoos and pigmented lesions faster, more efficient, and achievable in fewer sessions. The reduced reliance on thermal energy also means significantly less risk of collateral damage to surrounding tissues, which is especially important when treating darker skin types or heat-sensitive conditions like melasma.
Another major advantage of picosecond technology is its ability to create Laser-Induced Optical Breakdown (LIOB) when paired with fractional handpieces like MLA or DOE lenses. These lenses focus energy into precise micro-injury points within the dermis without breaking the skin’s surface, stimulating collagen and elastin remodeling from the inside out. This unique non-ablative approach allows providers to treat acne scars, fine lines, enlarged pores, and overall skin texture with minimal downtime, while achieving results that traditionally required ablative lasers.
Picosecond lasers also stand out for their versatility and safety across multiple wavelengths, typically offering 532 nm and 1064 nm options to address pigment at various skin depths and colors. Their combination of deeper penetration, higher peak power, and lower heat dispersion leads to clearer, smoother skin with less discomfort and faster healing. Whether for tattoo removal, pigmentation correction, or collagen stimulation, picosecond platforms consistently deliver more predictable, high-quality outcomes, making them a preferred choice in modern aesthetic medicine.
| Category | Specification |
|---|---|
| Wavelength | 1064/532nm |
| Pulse Duration | 300-350 PS |
| Peak Power | 1.67 GW (500mj 1064, 250mj 532) |
| Spot Sizes | 2–10mm |
| Wattage | 3000 W |
| Operating System | ARM-A13 CPU, Android |
| Cooling | Air & Water Advanced Cooling |
| Frequency (Hz) | 1–10 Hz |
| Device Size (L × W × H) | 96 × 48 × 95 cm |
| Device Weight | 109 kg |
| Maximum energy — 1064 nm | 500 mJ |
| Maximum energy — 532 nm | 250 mJ |
Each device package arrives with the core components and accessories needed for a smooth setup, ensuring you can integrate the equipment into your workflow quickly and confidently. Everything is organized to support reliable, everyday use from the start.
Every purchase is backed by guided onboarding and a full-service warranty that covers both the device and key consumables. This level of support helps protect your investment while ensuring consistent, long-term performance.
To help your team get the most out of the technology, each device includes access to in-depth education and training resources. From operational guidance to best-practice techniques, these programs equip users with the knowledge and confidence needed to deliver safe, effective, and consistent treatments.
The combination of a 20x Array Lens and DOE Lens enhances skin rejuvenation by optimizing Laser-Induced Optical Breakdown (LIOB), a phenomenon in which precisely focused ultrashort laser pulses ionize tissue at the focal point to create a microplasma. This rapid ionization produces controlled cavitation bubbles and micro-disruptions within the targeted layers, all while avoiding thermal damage to surrounding tissue. These microscopic injuries trigger natural collagen remodeling and skin renewal beneath the surface, allowing effective rejuvenation without harming the epidermis.
Inside our Nd:YAG technology
For North American DevicesThe premium crystal and quartz-cavity specifications described below apply to our North American device configurations.

Our North American Nd laser systems use high-optical-quality Nd single-crystal rods grown using the Czochralski process in an induction-heated iridium crucible.
Carefully controlled crystal growth helps achieve high Nd³⁺ dopant uniformity, excellent optical homogeneity, low internal stress and reduced wavefront distortion. These characteristics are important for maintaining consistent laser propagation through the gain medium and supporting a clean, stable beam with uniform energy distribution across the treatment spot.
We also specify our own optical coating requirements to support long-term durability and consistent optical performance in our North American Nd laser systems.
Rather than selecting laser rods based solely on cost, we specify higher-grade crystals for their optical quality, consistency and ability to withstand the high peak-energy demands of Q-switched and picosecond Nd systems.

Our North American Nd platforms utilize a precision quartz flow-tube and laser-cavity architecture selected for its high optical transmission, thermal stability and resistance to thermal shock.
The quartz assembly helps isolate and cool the Nd crystal while allowing efficient transmission of pump energy from the flashlamp. Combined with optimized cavity geometry and cooling, this helps maintain stable operating temperatures, consistent pumping of the crystal and repeatable laser output during high-energy operation.
The result is a laser head engineered around beam quality, energy stability and long-term optical performance, rather than simply minimizing component cost.
Inside PicoVive · Picosecond delivery
An aerospace aluminum articulated arm brings durable construction and flexible handpiece positioning to PicoVive’s picosecond configuration.

The arm’s connected segments and pivoting joints let the operator reposition the picosecond handpiece around the treatment area. The articulated structure supports the delivery assembly while allowing its orientation to be adjusted for the procedure.
Aerospace aluminum combines a lightweight structure with mechanical strength. Applied to the arm, it supports a balance of structural durability and manageable weight during positioning.
Confirm the supplied arm, handpiece and optics when selecting your PicoVive package.
Delivery for this device comes with the main unit, user manual, device-specific goggles, articulating arm, package-dependent handpieces/ lens, foot pedal, and a dust cover. Device support includes an extensive training program and device setup. Additional services include a two-year full-service warranty, including consumables.
Learn more about the system’s capabilities and the technology that drives its dependable performance. Explore how its engineered components work together to deliver consistent, high-quality results. See how this platform supports efficient, effective treatments across various aesthetic needs.
We believe long-term success comes from strong partnerships. Apolomed supports distributors and providers before, during, and long after installation through structured product training, clinical education, and responsive technical service.
Our global service network includes regional support teams and dedicated facilities, such as our U.S. distribution and service center in New York. This infrastructure ensures reliable communication, timely service, and consistent support across international markets.
Learn morePurchasing the PicoVive has been an excellent experience. Apolomed went above and beyond with customer service, resolving any questions or issues the same day. They even flew an engineer out to help with setup and hands-on training. Outstanding support all around.
I flew to Miami Dermatology after years of wanting my old neck tattoo removed, and I’m relieved I finally did. They explained that they were going to utilize a Picosecond device for my treatment. The tattoo started fading faster than I expected. The treatment was totally manageable, and I’m happy to see it get lighter with each visit.
I was pleasantly surprised by Apolomed’s dedication to service. When my practitioner accidentally broke the picosecond handpiece cable, Apolomed sent a service engineer to my office within 24 hours and fixed it—at no charge. They even serviced my IPL machine while they were here. That level of support is rare and genuinely appreciated.
Enter your name and email, and we will send this product's brochure link.
Request Brochure
After your laser treatment, avoid strong skincare products like retinoids, chemical peels, exfoliating scrubs, benzoyl peroxide, and harsh bleaching creams. Also, skip fragranced or alcohol-based products. Stick to gentle, soothing, and hydrating skincare until your skin heals.
PicoVive lists 1064/532 nm wavelengths and a 300–350 ps pulse duration. Its specifications also list a 2–10 mm spot-size range. Review the supplied handpieces and lenses alongside these figures when comparing systems.
PicoVive is the dedicated picosecond Nd:YAG platform. PicoFusion lists both picosecond and Q-switched nanosecond operation, together with a broader wavelength list. Compare the quoted configuration and accessories to determine which platform fits your planned services.
Pulse duration is one part of a device specification, not a guaranteed treatment count. A clinician must assess the individual concern and plan the course of treatment; the device specification alone cannot predict an individual result.
The technology section describes a Czochralski-grown Nd crystal, a quartz flow-tube and cavity assembly, and Apolomed's optical-coating specifications. These components are selected to support optical quality, cooling and durability in the laser head.
The listed device dimensions are 96 × 48 × 95 cm, with a weight of 109 kg. Confirm delivery access, electrical requirements, ventilation, cooling maintenance and the required laser-room setup with the installation team.
Tell us which treatments or devices you are evaluating, and a specialist can help you compare options.
Choose the site for your region so product availability, documentation, and support information match your location.
Products, education, and regional support for North American practices.
Products, documentation, and regional support for customers outside North America.